Skip to Content
03-9106060 sales@wise-t.co.il
comemso electronics GmbH. Exclusive Distributor in Israel

COMEMSO

https://www.wise-tech.co.il/web/image/product.template/30133/image_1920?unique=89a62e9

All-in-One AC/DC EV Charger Tester

Price on request

Tell us about your application and we'll send a tailored quote, including lead time and an expert recommendation.

This combination does not exist.

Download datasheet

 

Easy Chester Ultimate – 

One Guided Workflow – From Electrical Safety Testing to Comprehensive Reporting

The Easy Chester Ultimate is an advanced, all-in-one EVSE testing solution designed for commissioning, maintenance, troubleshooting, and verification of AC charging stations and DC fast chargers.

By simulating the behavior of an electric vehicle, the Easy Chester Ultimate initiates real charging sessions and performs comprehensive electrical safety, functional, and communication tests. Unlike conventional testing methods that require an electric vehicle and multiple separate instruments, it combines essential testing capabilities into a single portable system.

With real DC charging current, integrated safety measurements, automated test procedures, and PDF reporting, the Easy Chester Ultimate simplifies charger verification, reduces testing time, and provides documented results.

Key Features and Benefits

  • Complete AC/DC charger testing: Supports commissioning, preventive maintenance, troubleshooting, and functional verification of AC and DC charging stations.

  • Realistic EV simulation: Emulates electric vehicle behavior to initiate and monitor charging sessions under realistic operating conditions.

  • 400 V and 800 V vehicle simulation: Supports 330 V and 660 V battery emulation, eliminating the need for separate vehicles during testing.

  • Comprehensive electrical safety testing: Performs protective conductor, insulation resistance, RCD, loop impedance, residual voltage, and isolation monitoring checks, depending on configuration.

  • Advanced communication testing: Supports major EV charging protocols, including IEC 61851-1, SAE J1772, SAE J3400, DIN 70121, ISO 15118-2, and CHAdeMO.

  • High-power DC load testing: Supports test loads up to 30 kW / 90 A with one unit and up to 60 kW / 180 A using two cascaded units.

  • Fault simulation and diagnostics: Enables controlled fault simulation on CP, PP, and PE circuits to evaluate charger responses.

  • Guided testing workflow: A user-friendly 10.1-inch touchscreen simplifies test execution, measurements, and diagnostics.

  • Integrated reporting: Generates PDF test reports for documentation, maintenance records, and charger handover.

  • Portable and rugged design: Built for field operation, with a protective case suitable for demanding installation and maintenance environments.

COMEMSO


Realistic Charging Simulation with Advanced Safety Testing

The Easy Chester Ultimate establishes a charging session in the same way as a conventional electric vehicle, allowing technicians to verify charger operation under realistic conditions.

Beyond basic charging functionality, the system performs electrical safety measurements on both the grid and vehicle sides.

Grid-side testing includes:

  • Protective conductor resistance (RPE)

  • Insulation resistance (RISO)

  • Residual current device testing (RCD)

  • Fault loop impedance (ZS)

  • Phase rotation verification

Vehicle-side and connector testing includes:

  • Protective conductor and insulation resistance measurements

  • Residual voltage testing (UOFF)

  • RCD verification for AC charging

  • Phase rotation checks for AC charging

  • Insulation monitoring device (IMD) simulation

  • Control Pilot (CP), Proximity Pilot (PP), and Protective Earth (PE) fault simulation

These capabilities help technicians identify installation faults, verify protective functions, and document charger safety and operational performance.

Flexible DC Load Testing

The Easy Chester Ultimate supports multiple DC load configurations to accommodate different testing requirements.

The integrated DC test load supports 2 kW / 6 A for up to 45 seconds, extendable to 60 minutes with the optional Long Duration Unit.

For higher-power applications, an external load unit provides up to 30 kW / 90 A, while two cascaded load units increase testing capacity to 60 kW / 180 A. Each configuration supports operation for up to four hours.

The system is intended for commissioning, functional testing, maintenance, and troubleshooting rather than full-rated-power verification of high-power charging stations or formal standards-conformance testing.

Technical Specifications

ParameterSpecification
Weight15.7 kg
Dimensions60 × 33 × 40 cm
Protection ratingIP66 (case closed) / IP43 (case open)
Operating temperature−15°C to +40°C
Power supplyUSB-C, less than 100 W (vehicle adapter or power bank)
Display10.1-inch touchscreen
Internal storage128 GB
Charging interfacesAC Type 1 / Type 2, CCS1, CCS2, NACS, CHAdeMO (configuration-dependent)
Charging protocolsIEC 61851-1, SAE J1772, SAE J3400, DIN 70121, ISO 15118-2 with EIM (AC/DC), CHAdeMO up to version 2.0
Future protocol supportISO 15118-20 planned for Q1 2027
CP measurement range−13 V to +13 V
PP measurement range0–4,600 Ω
CP voltage accuracy±100 mV
PP resistance accuracy±5%
Battery voltage emulation330 V / 660 V (400 V / 800 V EV simulation)
Integrated DC test load2 kW / 6 A for up to 45 seconds
Extended DC load durationUp to 60 minutes with optional Long Duration Unit
External DC load – single unit30 kW / 90 A, up to 4 hours
External DC load – two units60 kW / 180 A, up to 4 hours
Grid-side safety measurements (optional)RPE, RISO, RCD, ZS, phase rotation
Connector-side safety measurements (optional)RPE, RISO, UOFF, RCD, AC phase rotation, IMD simulation
Test reportsPDF
Maintenance packageE-mail reporting, GPS location/address, and photo documentation

Designed for Professional EV Charging Infrastructure Testing

The Easy Chester Ultimate is an ideal solution for EV charging station installers, service technicians, maintenance providers, charging network operators, and infrastructure inspection teams.

By combining vehicle simulation, electrical safety testing, charging communication verification, DC load testing, and automated reporting, it provides a streamlined approach to verifying AC and DC charging infrastructure with a single integrated testing platform.


Connect. Select. Test. Verify. Report.

Five Simple Steps – From Setup to Comprehensive Test Reporting

The Easy Chester Ultimate simplifies AC/DC charging station testing with an intuitive, guided five-step workflow. From initial connection and test configuration to safety verification and final reporting, the entire process is performed directly on the device.

1. Connect

Identify the charging station and its firmware version, verify the appropriate charging interface, and connect the tester by following the on-screen instructions.

2. Select

Configure the test parameters, including charging protocol, voltage technology, test load, electrical safety measurements, and reporting requirements.

3. Test

The Easy Chester Ultimate automatically guides the operator through electrical safety and charging functionality tests, simulating defined electric vehicle behavior and applying the available fault simulation options.

4. Verify

Review charging initialization, voltage and current measurements, charging termination, and charger responses to simulated faults. Following repairs or maintenance, repeat the tests under the original conditions to verify corrective actions.

5. Report

Generate a comprehensive test report documenting charging station identification, test configuration, performed measurements, recorded values, detected deviations, and the technician's final assessment.

Intuitive Touchscreen Operation

The integrated 10.1-inch touchscreen provides a clear, centralized interface displaying test selection, current test steps, real-time measurements, and the next required action.

The system automatically detects the connected charging plug and performs internal module checks during startup, ensuring the tester is ready for operation.

All testing procedures are performed directly on the device, eliminating the need for external control equipment.

Built-in instructional videos and a multilingual digital user manual provide step-by-step guidance, simplifying operation and helping technicians perform tests efficiently and consistently.

COMEMSO


Comprehensive Test Results in a Single PDF Report

One Detailed PDF Report for Every Inspected Charging Station

The Easy Chester Ultimate automatically generates a comprehensive PDF report documenting the charging station's identification, performed tests, measured values, and overall PASSED or FAILED results.

The report provides clear, traceable documentation for commissioning, customer handover, preventive maintenance, troubleshooting, and post-repair verification.

1. Comprehensive Test Documentation

Each report includes detailed information about the charging station and the tests performed, including:

  • Charging communication sequences and protocol verification

  • Voltage and current measurements

  • Maximum charging power of the charging station

  • MAC-PLC address

  • Electrical safety test results

  • Clear explanations of individual measurements

  • Overall PASSED or FAILED test status

2. Customized Reporting and Easy Sharing

Enhance test reports with additional information relevant to the installation or maintenance activity:

  • Technician comments and observations

  • Charging station address and location details

  • Company logo for professional branding

  • PDF viewing on mobile devices

  • Convenient report sharing via e-mail using a mobile hotspot

3. Advanced Documentation with the Maintenance Package

The optional Maintenance Package extends reporting capabilities with additional field documentation features:

  • Automatic GPS location recording

  • Location information displayed as an address and map

  • Photographic documentation of visual inspections

  • Images of damaged components, defects, or installation issues

These features provide comprehensive maintenance records and simplify communication between technicians, service providers, and charging station operators.

Clear and Intuitive Test Result Display

The Easy Chester Ultimate's user interface provides a structured overview of each test, including the selected safety measurement, relevant measurement fields, and test progress.

For example, during an RCD (Residual Current Device) test, the screen displays the selected safety check, measurement parameters, and execution status, allowing technicians to monitor the procedure and review the results.

The interface also provides convenient access to safety test execution and report archiving functions.

From electrical safety verification to professional documentation, the Easy Chester Ultimate delivers a complete and traceable testing workflow in one integrated solution.

COMEMSO

Ultimate brochure, page 6Report functions in the datasheet


Advanced Electrical Safety and Functional Testing for AC/DC EV Chargers

Safety First. Functionality Next.

The Easy Chester Ultimate, equipped with the optional comISO safety testing module, combines comprehensive electrical safety measurements with charging functionality tests in a single, guided workflow.

The system verifies essential protective measures on both the grid side and the electric vehicle charging interface, helping technicians identify electrical faults, assess protective functions, and verify the safe operation of AC and DC charging stations.

Comprehensive Electrical Safety Testing

Safety FunctionGrid SideEV InterfaceTest PurposeApplicable Standards
RPE – Protective Conductor ResistanceYesYesVerifies protective conductor continuity and resistance.VDE 0100-600, VDE 0113-1, VDE 0413
RISO – Insulation ResistanceYesYesEvaluates insulation resistance during the applicable test sequence.VDE 0100-600, VDE 0113-1, VDE 0413
UOFF – Residual VoltageNoYesMeasures residual voltage at the vehicle charging interface.VDE 0113-1
tRCD – Residual Current Device TestingYesYesVerifies RCD protective response under defined test conditions.VDE 0122-1, VDE 0100-600, VDE 0113-1, VDE 0413
IMD / RISO SimulationNoYesEvaluates the charging station's insulation monitoring functionality.—
Zs – Fault Loop and Line ImpedanceYesNoMeasures L–PE fault loop impedance and L–N line impedance.—
Phase RotationYesYes (AC only)Verifies the correct phase sequence of the electrical supply.—

Advanced Fault Simulation and Protection Verification

The Easy Chester Ultimate supports controlled fault simulation to evaluate how charging stations respond to abnormal electrical conditions.

CP – Control Pilot Short Circuit

Simulates a short circuit in the Control Pilot circuit to verify that the charging station interrupts the charging process as expected.

PP – Proximity Pilot Short Circuit or Cable Break

Simulates defined Proximity Pilot faults, including short circuits and cable interruptions, to evaluate charger response under repeatable test conditions.

PE – Protective Earth Interruption

Simulates an interruption of the protective conductor to verify the charging station's configured protective response.

AC/DC Isolation Fault Simulation

Applies defined AC or DC isolation fault conditions to evaluate the operation of the charging station's insulation monitoring system.

These capabilities support commissioning, preventive maintenance, troubleshooting, and verification following corrective maintenance.

Supported Charging Interfaces and Communication Protocols

One Versatile Tester for AC Wallboxes and DC Fast Charging Stations

The Easy Chester Ultimate supports multiple charging interfaces and communication protocols, making it suitable for EV charging infrastructure across Europe, North America, and Asia.

The system can be configured according to regional charging standards, connector types, electrical safety requirements, and optional testing capabilities.

AC Charging – Functional and Communication Testing

The Easy Chester Ultimate supports functional verification of AC charging stations, including charging control, low-level signaling, and configured high-level communication.

Supported standards and interfaces:

  • IEC 61851-1

  • SAE J1772

  • SAE J3400

  • ISO 15118-2/-3, depending on configuration

  • Type 1 and Type 2 charging connectors

DC Charging – CCS and NACS

The system enables direct verification of DC charging functionality and communication without introducing an external protocol converter into the test path.

Supported standards and interfaces:

  • DIN 70121 – included in the published base configuration

  • ISO 15118-2/-3 – optional

  • CCS1 and CCS2

  • NACS

  • SAE J3400 for NACS DC charging

Direct communication testing helps technicians identify protocol-related issues and verify charging station operation under defined conditions.

CHAdeMO DC Charging

The Easy Chester Ultimate also supports CAN-based CHAdeMO charging systems for international charging infrastructure and maintenance applications.

Key capabilities:

  • CHAdeMO protocol support up to version 2.0

  • DC charging functionality verification

  • Charging communication testing

  • Support for the released CHAdeMO configuration

400 V and 800 V Vehicle Simulation

Modern DC fast charging stations must support vehicles with different battery voltage architectures.

The Easy Chester Ultimate simulates both 400 V and 800 V vehicle technologies, allowing technicians to evaluate charging station behavior without requiring two separate electric vehicles.

Key benefits:

  • Battery emulation at 330 V and 660 V

  • Verification of charging behavior for different vehicle voltage architectures

  • Repeatable testing under defined conditions

  • Reduced equipment and vehicle requirements during commissioning and maintenance

ISO 15118 Communication Support

The Easy Chester Ultimate supports ISO 15118-2 with External Identification Means (EIM) authentication for both AC and DC charging.

EIM enables charging authorization through an external identification method rather than requiring the vehicle to perform Plug & Charge authentication.

Support for ISO 15118-20 is planned for the first quarter of 2027.

The AFIR regulatory framework introduces EN ISO 15118-20 technical requirements from January 1, 2027, for relevant newly installed or renovated publicly accessible charging points, subject to the applicable regulatory provisions.

Easy Chester Ultimate combines electrical safety verification, charging functionality testing, protocol diagnostics, and fault simulation in one professional testing platform.


One Complete Solution for EV Charger Commissioning, Maintenance, Service, and Repair

Comprehensive Testing Throughout the Charging Station Lifecycle

The Easy Chester Ultimate provides a versatile, all-in-one testing solution for commissioning, preventive maintenance, troubleshooting, and repair verification of AC and DC charging stations.

By using standardized, repeatable test procedures, technicians can consistently evaluate charging station performance, compare measurement results across different locations, identify faults, and maintain comprehensive service records.

Commissioning – Verify Before Handover

Perform comprehensive installation, electrical safety, communication, and charging functionality tests before the charging station enters service.

Verify proper operation, identify potential installation issues, and document test results to support a professional and reliable customer handover.

Maintenance – Ensure Continued Reliability

Perform scheduled inspections and preventive maintenance using predefined, repeatable test procedures.

Evaluate electrical safety, charging functionality, and system condition while maintaining detailed records to monitor performance over time and identify potential issues before they lead to failures.

Service – Identify and Diagnose Faults

Efficiently reproduce reported charging issues and systematically isolate their causes.

Independently evaluate the electrical supply, protective functions, control signals, and charging communication. Compare charger error messages with actual measurements to identify faults and support effective troubleshooting.

Repair – Verify Corrective Actions

Confirm the effectiveness of repairs by performing relevant tests before and after corrective maintenance.

Compare the results under consistent test conditions, verify restored functionality, and retain both sets of measurements for complete service documentation and traceability.

From initial commissioning to ongoing maintenance and repair, the Easy Chester Ultimate delivers consistent testing, accurate diagnostics, and professional documentation throughout the charging station lifecycle.

COMEMSO


Downloads

Need another document? Full specifications, declaration of conformity or user manual: ask us

WhatsApp Call Get Quote