Ametek SECM Scanning Electrochemical Microscopy

Ametek SECM Scanning Electrochemical Microscopy

Manufacturer:
Ametek Scientific Instruments

More Products by Ametek Scientific Instruments
Solution Type: Scanning Electrochemical Systems
secm

The SECM integrates a positioning system, a bipotentiostat, and an ultramicroelectrode tip. The positioning system moves the tip close to the surface of the sample. The bipotentiostat polarizes both the sample and the  tip independently and measures both resulting currents. The tip is an ultramicroelectrode with a specific tapered polish and active radius lower than 100 microns. The positioning system scans the measurement tip and charts position with measured electrochemical parameters, creating a data map of local current. Approach Curves are used as an electrochemical means by which to position the probe in Z sufficiently close to the sample to be in the local imaging zone. Current at the tip is charted as the tip is incremented towards the sample. When the probe is sufficiently close to the sample (a distance of 2-4 times that of the probe diameter) the measured current at the tip transitions from a bulk response to a local response. Over a region of high conductivity, a Nerstian response provides a local current enhanced over that of the bulk current. However, local current is decreased relative to bulk value over areas of low conductivity of the sample as mass-transport is hindered to the tip. The Soft Stylus Probe technology from LEPA-EPFL, Switzerland, offers a convenient method of controlling the tip – sample distance without the need for complicated feedback electronics. Constant distance measurements are especially important when sample topography can affect the electrochemical response such as rough and corrugated surfaces. In addition, the soft probe technique has been shown to be ideal for soft tissue samples and has been applied to the detection and staging of cancer. A common experiment in SECM is Generator-Collector Mode. Here one channel of the bipotentiostat polarizes the sample; where the other channel polarizes the tip. Similar to a Rotating – Ring Disk Electrode (RRDE) experiment, one electrode generates an electrochemical reaction, the products of which are subsequently measured at the other electrode. A SECM does this while adding the extra dimension of spatial resolution to the data, and being able to change from Sample Generation – Tip Collection (SG-TC) to Tip Generation –Sample Collection (TG-SC) often by simply changing polarization levels. Since the imaging mechanism is electrochemistry, the applications of a SECM are as varied as the applications of electrochemistry itself. Some key applications are biological sensors, reaction kinetics, porous membrane study, fuel cell catalysts, and corrosion mechanisms.



Request for Quotation



Interested in receiving promotional mail

  • For the determination of localized electrochemical events such as electrode kinetics, metal dissolution and studies of bio-logical samples
  • Capable of Approach Curves experiments and both Feedback Mode and Generator-Collector Mode imaging modes
  • AC-SECM technique operates without need for electrochemical mediator, Useful for corroding systems
  • Constant-Distance operation in conjunction with a topographic measurement technique (e.g. OSP) or Constant Distance SECM with EPFL Soft Stylus Probe technology